This question was closed without grading. Reason: Other
Jun 17, 2016 15:08
7 yrs ago
1 viewer *
English term

accuracy MPE EM

English to Spanish Tech/Engineering Mechanics / Mech Engineering metrology
Any idea, please?

*****Confirmation of the duplex accuracy MPE EM is only possible at the customer site after final installation.****

Thanks in advance!

Discussion

slothm Jun 21, 2016:
The error for a Koba step gage is meassured in micrometers.
Chances are that EM stands for µm.
slothm Jun 21, 2016:
Sorry , E is next to R.
Taña Dalglish Jun 21, 2016:
@ slothm I assume you mean "MPE" and not "MPR"? = Maximum Permissible Error. However, would you know by chance what "EM" mean? Can you explain "duplex accuracy" as all my research revealed nothing! Regards. Taña.
slothm Jun 20, 2016:
Sin duda,

MPR = Maximim Permisible Error.

Reference comments

11 mins
Reference:

OIML R 136-1 - Organisation Internationale de Métrologie Légale
https://www.oiml.org/en/files/pdf_r/r136-1-e04.pdf
Maximum permissible errors (MPE). 2.3 .... metrological controls applied by the national metrological ... Recommendation, the definitions below apply. T.1.

R 117-1 - Organisation Internationale de Métrologie Légale
https://www.oiml.org/en/files/pdf_r/r117-1-e07.pdf
other than water. Part 1: Metrological and technical requirements .... Maximum permissible errors and significant faults on calculators ....................................27. 2.9. Indications . ..... EM = electromagnetic ... MPE = maximum permissible error.

See terminology on page 2 of link above
MPE = maximum permissible error
EM = electromagnetic

Makes sense?
HTH


--------------------------------------------------
Note added at 39 mins (2016-06-17 15:48:04 GMT)
--------------------------------------------------

Marta:

Can we have more context please? I am not sure about "duplex accuracy", nor "EM" without more information. Thanks.

Is "duplex accuracy" defined elsewhere in your document? I've found other references to "dual accuracy", so I don't understand "duplex".

--------------------------------------------------
Note added at 50 mins (2016-06-17 15:59:02 GMT)
--------------------------------------------------

http://www.pmargage.com/kobastepmore.shtml
KOBA-step® Gage Bar (KOBA-step is a registered TM). "Gage", although I would have said "gauge" (British English), so it is assumed your text is American English?

--------------------------------------------------
Note added at 55 mins (2016-06-17 16:04:02 GMT)
--------------------------------------------------

http://publications.npl.co.uk/npl_web/pdf/mgpg42.pdf
Kolb & Baumann GmbH & Co. KG
(website: www.koba.de/ index.php?lang=english) are manufacturers of gauge
blocks, ball plates (KOBA-check), ball bars and step gauges (KOBA-step). They can
be contacted at:
Kolb & Baumann GmbH & Co. KG
Fabrik für Präzisions-Messzeuge
Daimlerstraße 24
DE-63741 Aschaffenburg
The UK distributor is OPUS

--------------------------------------------------
Note added at 58 mins (2016-06-17 16:07:06 GMT)
--------------------------------------------------

http://www.koba.de/index.php?id=29&L=1
KOBA Ball Bar (although this is not used in your case)
one-dimensional, removeable test piece with spheroidally targets

scope of application:
- monitoring and traceability of large volume CMM's, e.g. horizontal arm and bridge type CMM
- checking of opto-tactile measurement systems like Lasertracker
Note from asker:
Duplex accuracy doesn't appear in any other part but these are the previous sentences. ***** - Due to technical reasons, the pre acceptance test will be made with Koba step gage. Pre acceptance with ball bar is not possible. Confirmation of the duplex accuracy MPE EM is only possible at the customer site after final installation.*****
Thank you for your help!
Something went wrong...