Kontekst:
Dokument dot. kompensacji mocy biernej odbiorców nietrakcyjnych kolei

Required amount of reactive power and the power of the compensating device was determined by the maximum integrate effect criterion. The introduction of reactive power compensation has reduced the voltage change by 5%, and reduced losses in the transformer by 1857 kWh during the year.
Biurobob
Local time: 12:25
kryterium maksymalnego poziomu integracji
Explanation:
Four interconnection requirements, related to local area operating characteristics of the power system, are analyzed: the steady-state voltage variation; the power margin; the low-voltage ride-through capability; and transient stability. The maximum integration level is first determined as limited by each individual interconnection requirement. Then, the maximum integration level complying with all interconnection requirements is determined. Results show that a wind farm with rated power up to 5.5–6.3 % of the short-circuit power, depending on the reactive power compensation, can be connected to a given grid point while respecting more recent grid codes.
https://link.springer.com/article/10.1007/s40313-013-0074-6
Selected response from:

Frank Szmulowicz, Ph. D.
United States
Local time: 06:25
Grading comment
dziękuję
4 KudoZ points were awarded for this answer



Summary of answers provided
2kryterium maksymalnego poziomu integracji
Frank Szmulowicz, Ph. D.


  

Answers


5 hrs   confidence: Answerer confidence 2/5Answerer confidence 2/5
kryterium maksymalnego poziomu integracji


Explanation:
Four interconnection requirements, related to local area operating characteristics of the power system, are analyzed: the steady-state voltage variation; the power margin; the low-voltage ride-through capability; and transient stability. The maximum integration level is first determined as limited by each individual interconnection requirement. Then, the maximum integration level complying with all interconnection requirements is determined. Results show that a wind farm with rated power up to 5.5–6.3 % of the short-circuit power, depending on the reactive power compensation, can be connected to a given grid point while respecting more recent grid codes.
https://link.springer.com/article/10.1007/s40313-013-0074-6

Frank Szmulowicz, Ph. D.
United States
Local time: 06:25
Native speaker of: Native in EnglishEnglish, Native in PolishPolish
PRO pts in category: 495
Grading comment
dziękuję
Login to enter a peer comment (or grade)



Login or register (free and only takes a few minutes) to participate in this question.

You will also have access to many other tools and opportunities designed for those who have language-related jobs (or are passionate about them). Participation is free and the site has a strict confidentiality policy.

KudoZ™ translation help

The KudoZ network provides a framework for translators and others to assist each other with translations or explanations of terms and short phrases.


See also:
Term search
  • All of ProZ.com
  • Term search
  • Jobs
  • Forums
  • Multiple search