https://www.proz.com/kudoz/english-to-bosnian/medical-general/6245204-vergence-facility.html

Glossary entry

English term or phrase:

vergence facility

Bosnian translation:

prilagodbena sposobnost/mogućnost fuzije, sposobnost/mogućnost fuzije da se prilagodi

Added to glossary by LogosART
Dec 17, 2016 12:53
7 yrs ago
1 viewer *
English term

vergence facility

English to Bosnian Other Medical (general) eye tests
In addition to the cycloplegic refractive error, the following binocular vision related data was also acquired: vergence facility, vergence amplitudes, accommodative facility, accommodative amplitudes, near point of convergence, stereopsis, and a standardized symptom scoring scale.
Change log

Dec 25, 2016 13:23: LogosART Created KOG entry

Proposed translations

8 hrs
Selected

prilagodbena sposobnost/mogućnost fuzije, sposobnost/mogućnost fuzije da se prilagodi

prilagodbena sposobnost/mogućnost fuzije
sposobnost/mogućnost fuzije da se prilagodi

______________

PRIJEDLOG temelji se na nizozemskom prijevodu i dolje navedenoj definiciji pojma

Prisma Flipper (Fusie Aanpassingsvermogen)
(Eng. “Vergence facility”)
https://hubl.hu.nl/sites/hu.learn.mentorix.dk/files/user-fil...


Razvoj normalne sposobnosti fuzije
http://knezovic.com.hr/sinoptofor/
http://www.poliklinikafokus.hr/oprema/

Djetetu treba napraviti kompletan oftalmološki pregled koji uključuje i neka, za djecu specifična testiranja (određivanje kuta škiljenja, testiranje mogućnosti fuzije, provjera binokularnog vida, sposobnost fiksacije, skijaskopija i dr.).
http://www.vasezdravlje.com/printable/izdanje/clanak/634/

________________

Vergence facility, defined as the number of cycles per minute that a stimulus can be fused through alternating base-in and base-out prisms, attempts to capture the ability of the fusional vergence system to respond rapidly and accurately to changing vergence demands over time. The purpose of this study was to critically evaluate vergence facility in a young adult population.

METHOD. Binocular-vision-symptom level was determined through a self-report questionnaire, and an inclusion / exclusion examination was performed on each subject to determine those who could be optimally corrected to 20/20 Snellen acuity in each eye, had normal eye alignment at distance and near, and normal ocular health. Ultimately, 40 subjects (20 in each of the control and symptomatic groups) were tested using a series of 32 randomly presented magnitudes of BI / BO flip prisms (16 each at 4.0 M and 0.4 M) based on Morgan's norms and pilot data. Vergence facility response was computer recorded for one minute with each flip prism. RESULTS. Horizontal vergence facility responses differed among those with and without symptoms by an amount that depended upon the magnitudes of the BI / BO flip prisms. A single flip prism, 3BI / 12BO, was found to optimally differentiate between groups at distance (t-value=2.80 df=38 p=0.008) and near (t-value=3.85 df=38 p=0.0004). CONCLUSION. The results of this study suggest that the vergence system nearly resets its zero point between distance and near. From a clinical standpoint, the results show that the diagnosis of binocular vision abnormalities can be improved using vergence facility testing. The recommended vergence facility test is easily implemented using a commonly available flip prism (3BI /12BO) with clinical failure criteria that are easily recalled (12 cpm at distance, magnitude of BO prism; 15 cpm at near, sum of the Bl and BO magnitudes). Supported in part by Grant R21 EY09633 (B Wick)
http://www.aaopt.org/vergence-facility-establishment-clinica...
Something went wrong...
4 KudoZ points awarded for this answer.